The EIZO RadiForce GX560 MammoDuo integrates two 5-megapixel (2048 x 2560) LCD monochrome monitors side by side with a thin bezel for comfortable breast image viewing on a specially designed stand. You can change the two monitors' height, tilt, and swivel without any gaps appearing between them. The RadiForce GX560 is also available and sold as a single monitor with its stand.
The narrow bezel design offers a distraction-free viewing that helps your eyes swiftly move from one monitor to another. These monitors are an excellent option for you to focus on your work and maintain optimal performance at your medical imaging practice.
These monitors include an easy-to-use RadiCS UX2 quality control software & calibration sensor (sold separately) that performs a precise calibration conforming to DICOM Part 14. They also facilitate quality control standards that are compliant with ACR Practice Guidelines and other common standards for digital mammography monitors.
Additionally, you can rest assured that these displays will maintain the high performance and functionality necessary for diagnostic use while providing the benefit of lower power consumption when compared to most monitors. The GX560 MammoDuo was also designed to promote energy efficiency.
Highlights:
- High-Definition mammography images
- Multi-modality monitors that improve workflow thanks to its Work-and-Flow technology
- Anti-glare (AG) and anti-reflection (AR)
- Optimal quality control with RadiCS UX2 quality control software
- Display deep blacks and bright whites without any washout
- Switch-and-Go function for performing improvement
Optimum Breast Screening Technology
The RadiForce GX560 was recognized by the U.S. Food and Drug Administration with an FDA 510(k) clearance for tomosynthesis and mammography. This ensures that the monitor can display detailed breast screening images where high performance is essential.
The GX560 adopts an LTPS (Low Temperature Polysilicon) panel, which allows the monitor to achieve a maximum brightness of 2,500 cd/m2. Furthermore, it has a contrast ratio of 1700:1, displaying deep blacks and bright whites without any washout. This makes it suitable to use with breast tomosynthesis and mammography which require clear visibility.
Work-and-Flow Technology
In this digital era, radiologists view an increasing amount of information on their screens. The unique EIZO's Work-and-Flow technology helps make the imaging workflow's complexity easier with new functions developed with the radiologist in mind. Medical imaging users can take advantage of Work-and-Flow features with the RadiForce monitor and bundled RadiCS LE software.
Barrier-Free Workstyle
The Switch-and-Go function allows you to operate two different workstations at the same time with a single mouse and keyboard. You can work across different monitors by moving the cursor from one screen to another or by switching the signals between them without having to change your mouse and keyboard each time.
Space Saving Compact Design
Due to the thinner bezels, the GX560 MammoDuo is slimmer than two conventional 5 megapixel monitors by 67 mm horizontally, 36 mm vertically and 20.5 mm in depth. The entire space occupied by the monitors was reduced by 22%, creating a more open environment with expanded viewing space.
Quick and Easy Focus
The Point-and-Focus function allows you to quickly select and focus areas of your concern using just your mouse and keyboard. You can change the brightness and grayscale tones of specific points on the screen to make interpretation easier and more accurate.
High-Definition Mammography Images
The high-definition 5-megapixel monitors allow you to see smaller details that are essential in digital mammography. The high resolution retains important information to prevent decreased image quality and pixelation that occurs when viewing at a lower resolution.
The monitor has a response time of 12 milliseconds, making it ideal for smoothly and continuously viewing tomographic images such as breast tomosynthesis, MRI and CT. In addition, with a pixel pitch of 0.165 mm and 10-bit (1,024 tones) simultaneous grayscale display, subtle density differences can be easily distinguished.
True to the Source Data Images
To meet the performance standard, a medical monitor needs to be capable of high brightness. Still, the pixel aperture ratio must increase to achieve high brightness in an LCD panel. This causes a typically unavoidable decline in sharpness. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored.
These monitors allow you to display an image safely that is true to the original source data, even at high brightness levels. MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing.
Anti-glare (AG) and Anti-reflection (AR)
These monitors offer anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for bright environments as it drastically reduces glare from ambient lighting. AR treatment is ideal for moderately lit environments to reduce mild screen glare while maintaining crisp text and images.
Make Precise Diagnosis
This brand carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. At startup or upon wakeup, the patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time. This allows medical images to be faithfully reproduced with stable brightness and grayscale.
Manage Effortless Quality Control
With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor. Simple calibration using the monitor backlight sensor is also supported.
Different Modes for Different Modalities
The CAL Switch function allows you to choose various modes for different modalities such as mammography, MRI, and endoscopy. It can be conveniently accessed using the monitor's front panel buttons to easily switch to optimal image viewing conditions.
Power Save Mode
A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve energy when not in use.
Rest Assured with Medical Qualifications
The monitors meet the strictest medical, safety, and EMC emission standards.
Specifications:
Screen Technology/Type
Monochrome (IPS)
Backlight
LED
Screen Size
54.1 cm / 21.3"
Native Resolution
2048 x 2560 (4:5 aspect ratio)
Viewable Image Size (H x V)
337.9 x 422.4 mm
Pixel Pitch
0.165 x 0.165 mm
Display Colors
10-bit (DisplayPort): 1,024 from a palette of 16,369 (14-bit) tones
8-bit: 256 from a palette of 16,369 (14-bit) tones
Viewing Angles (H / V, typical)
178° / 178°
Brightness (typical)
2500 cd/m2
Recommended Brightness for Calibration
1000 cd/m2, 600 cd/m2
Contrast Ratio
1700:1
Response Time (typical)
12 ms (black-white-black)
Input Terminals
DisplayPort x 2, DVI-D (dual link)
Output Terminals
DisplayPort (daisy chain)
Digital Scanning Frequency (H / V)
31 - 135 kHz / 23 - 61 Hz
Upstream
USB 2.0: Type-B x 2
Downstream
USB 2.0: Type-A x 2
Power Requirements
AC 100 - 240 V: 50 / 60 Hz
Typical Power Consumption
28 W
Maximum Power Consumption
79 W
Power Save Mode
1 W or less
Sensor
Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor
Brightness Stabilization
Yes
Digital Uniformity Equalizer
Yes
Work-and-Flow
Switch-and-Go, Point-and-Focus
Preset Modes
CAL Switch (DICOM, CAL1, CAL2, Text)
OSD Languages
English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Net Weight
GX560-MD, GX560-AR-MD:
17.1 kg
GX560, GX560-AR:
8 kg
Net Weight without Stand
5.2 kg
Hole Spacing (VESA Standard)
100 x 100 mm
Certifications
GX560, GX560-AR:
CE (Medical Device), EN60601-1, ANSI/AAMI ES60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA
510(k) Clearance for Breast Tomosynthesis, Mammography, and General Radiography
Monitor Quality Control Software RadiCS
Suported
Supplied Accessories
Signal Cables
GX560-MD, GX560-AR-MD:
DisplayPort (3 m) x 4, DisplayPort (1 m)
GX560, GX560-AR:
DisplayPort (3 m) x 2
Others
GX560-MD, GX560-AR-MD:
AC power cord (3 m) x 2, USB Type-A - USB Type-B cable (3 m) x 4, Utility Disk (RadiCS LE, PDF installation manual), instructions for use
GX560, GX560-AR:
AC power cord (3 m), USB Type-A - USB Type-B cable (3 m) x 2, Utility Disk (RadiCS LE, PDF installation manual), instructions for use